Test report
Internal batch protocolE-mail: labs@cryopept.com
Web: www.cryopept.com
Report 20438
Task number#107654
Testing ordered14 JUL '26
Sample received17 JUL '26
ClientCryopept Labs
SampleBAC Water 3 ml
Manufacturerwww.cryopept.com
BatchBACW-3ML / -
Sample descriptionSealed 10 ml glass vial, aluminium crimp cap, intact seal. See attached photographs.
Tests requestedAssessment of a solvent vial. Identity and content by GC, sterility by membrane filtration.
ResultsAnalyteResult
Bacteriostatic waterConforms
Benzyl alcohol0.90 %
SterilityPass
CommentsSample conforms to specification. Sterile filtered, no growth detected.
Analysis conducted21 JUL '26
MethodGC · sterility
Verify this report at cryopept.com/coa with the following unique keyACU3QHYWXYZ7
This document is Cryopept Labs' own internal batch protocol, not a third-party certificate.For laboratory research use only · not for human or veterinary use